Welcome to the CAT Facility

Welcome to the Cytometry and Antibody Technology Core Facility
Welcome New Users!
Instructions for getting trained to use CAT Facility instruments and the available services can be found on our New User page. If you have any questions please don’t hesitate to contact the CAT Facility Staff.
Institute for Translational Medicine Core Facility Grant
The ITM wants to help you take advantage of core facility resources, awarding up to $5,000 to offset any costs associated with using one of UChicago’s Core Facilities.
Instrument Status
The CAT Facility staff works hard to ensure the instruments are working properly. In the event that there are ongoing issues with any of the instruments the status will posted at the bottom of this page.
Spectral Flow Cytometry
Get started in the spectral flow cytometry world
Blog
Whole Blood Cryopreservation and The Discovery of an Alternative Blocking Method
When working with patients, samples are rarely collected from all of the patients on the same day. That leaves two options for running samples: cells can be collected and run on the same day over the course of the study or cells can be cryopreserved and run at one...
Vibration Study Postmortem
Last week, the university conducted a vibration study by dropping 5000lb (2268kg) weights from 15ft (4.6m) in four locations near the CAT Facility Lab. In biology terms, that's like dropping a rhinoceros from the height of a giraffe. Why? No idea. But when life...
Optimized Voltages on Benchtop Analyzers
The voltages on a flow cytometer are one of the more challenging settings to adjust properly. If voltages are too high or too low, the data looks terrible and is potentially unusable. Once voltages have been set and data have been collected there is no way to go back...
Instrument Status
See notes below if bars are yellow or red. Click on each instrument to access the instrument-specific page.
- No Issues 0%
- Minor issues 0%
- Can not be used 0%
- Aurora-B
- Aurora-G
- Aurora-R
- Penteon 5-30
- Quanteon 4-25
- Fortessa 4-15
- Fortessa HTS 4-15
- Attune NxT 4-14
- CytoFLEX LX 4-16
- Bigfoot
- Aria Fusion 5-18
- AriaIII
- Tyto
- Jonas Center Quanteon
- PME Fortessa
- PME Aurora
- Image Stream MarkII
- Luminex 200
- MSD Quickplex SQ120
04/18/25 Aria Fusion issue: The waste sensor is defective and will not allow us to run the instrument. We swapped the air compressor to the AriaIII and got that one going. BD has been informed of the issue and we are waiting for a visit from a service engineer.